AHU 400 Ceiling/1

AHU 400 Ceiling is a ventilation unit in Ensy its AHU series. AHU 400 Ceiling left and right variant has a capacity of 400 m³ / h and is suitable for flats / houses and villas. The models are based on the best available technology here has resulted in: Energy efficiency and low noise. Very user management and an appealing design. AHU-400 Ceiling is designed for installation in ceiling or alternatively wall mounting. AHU- aggregates are of course designed to cope with the requirements of current regulations. In addition manages aggregates requirements of Passive House standard.

Control panel with 10 m cable is supplied loose together with the AHU – unit.

TECHNICAL DATA AHU-400 Ceiling

  Heating battery -Phase/Voltage (50Hz/VAC) ~1 / 230
  -Power consumption (W) 2x750
  Fans -Phase/Voltage (50Hz/VAC) ~1 / 230
  -Total current for both fans at NORM operation (A) 0,40
  Fuse   (A) 10
  Automatic system     Integrated
  Filter class Superpleat   F7
  Thermal insulation Sider/endevegger   40 mm
  Tailgate   20 mm
   Front door   25 mm
  Weight (kg)   62

 

Trade name

Ensy

 

Product name

AHU-400 HH AHU-400 HV

 

ErP compliance

2016

 

Unit category

RVU

 

Unit type

BVU

 

Drive

Variable speed

 

Heat recovery type

Regenerative

Thermal efficiency of HRS

78

%

qVd max

420

m³/h

PtU

100

Pa

P el,max

350

W

Sound power level   Lwa

43

dB(A)

qv ref

294

m³/h

PtU ref

50

Pa

Max external and Internal Leakage. Overpressure 250 Pa

1,9

%

Max external and Internal Leakage. Underpressure 250 Pa

1,7

%

Annual operation hours   ta

8760

 h/a

Primary energy factor    pef

2,5

 

Net ventilation rate    qnet

1,3

m³/hm²

MISC (ducted)

1,1

 

CTRL (local demand)

0,65

 

X value.  Motor drive characteristic  (Variable speed)

2

 

SPI Specific power input  (measurement)

0,00053

kW/m³/h

Total hours heating season   th  Average

5112

h/a

Total hours heating season   th  Cold

6552

h/a

Total hours heating season   th  Warm

4392

h/a

Average temperature difference  ∆Th  Average

9,5

K

Average temperature difference  ∆Th  Cold

14,5

K

Average temperature difference  ∆Th  Warm

5

K

Thermal efficiency  ηh

0,75

 

Specific heat capacity   Cair

0,000344

kWh/m³K

Reference natural ventilation rate qref

2,2

m³/hm³

Thermal efficiency of HRS   ηt

0,78

 

Defrosting period   t defr  Average

168

h/a

Defrosting period   t defr  Cold

1003

h/a

Defrosting period   t defr  Warm

0

h/a

Average temperature difference defrost  ∆Tdefr  Average

2,4

K

Average temperature difference defrost  ∆Tdefr  Cold

5,2

K

Average temperature difference defrost  ∆Tdefr  Warm

0

K

AEC average. Annual electrical consumption per 100 m²

281

kWh/a

AEC cold

281

kWh/a

AEC warm

281

kWh/a

AHS Average. Annual heating saved per m²

44,4

kWh/a

AHS Cold

87,0

kWh/a

AHS Warm

20,1

kWh/a

SEC Average. Specific energy consumption

-37,4

kWh/m²a

SEC Cold

-79,9

kWh/m²a

SEC Warm

-13,1

kWh/m²a

Efficiency Class

A

 

Airflow (Supply) [m³/h]
Pressure (Supply) [PA]
AHU-400 HH

AHU-400 HV
Airflow (Extract) [m³/h]
Pressure (Extract) [PA]
AHU-400 HH

AHU-400 HV
 

Document Name 

Model

Language

  Bruks- og monteringsanvisning AHU-400 HV1 and HH1   Norsk
 
     
       
  Koblingsskjema/Wiring diagram AHU-400 HV and HH Left/Right Norsk/English