AHU 400 Ceiling/1
AHU 400 Ceiling is a ventilation unit in Ensy its AHU series. AHU 400 Ceiling left and right variant has a capacity of 400 m³ / h and is suitable for flats / houses and villas. The models are based on the best available technology here has resulted in: Energy efficiency and low noise. Very user management and an appealing design. AHU-400 Ceiling is designed for installation in ceiling or alternatively wall mounting. AHU- aggregates are of course designed to cope with the requirements of current regulations. In addition manages aggregates requirements of Passive House standard.
Control panel with 10 m cable is supplied loose together with the AHU – unit.
TECHNICAL DATA AHU-400 Ceiling
Heating battery | -Phase/Voltage | (50Hz/VAC) | ~1 / 230 |
-Power consumption | (W) | 2x750 | |
Fans | -Phase/Voltage | (50Hz/VAC) | ~1 / 230 |
-Total current for both fans at NORM operation | (A) | 0,40 | |
Fuse | (A) | 10 | |
Automatic system | Integrated | ||
Filter class | Superpleat | F7 | |
Thermal insulation | Sider/endevegger | 40 mm | |
Tailgate | 20 mm | ||
Front door | 25 mm | ||
Weight | (kg) | 62 |
Trade name |
Ensy |
|
Product name |
AHU-400 HH AHU-400 HV |
|
ErP compliance |
2016 |
|
Unit category |
RVU |
|
Unit type |
BVU |
|
Drive |
Variable speed |
|
Heat recovery type |
Regenerative |
|
Thermal efficiency of HRS |
78 |
% |
qVd max |
420 |
m³/h |
PtU |
100 |
Pa |
P el,max |
350 |
W |
Sound power level Lwa |
43 |
dB(A) |
qv ref |
294 |
m³/h |
PtU ref |
50 |
Pa |
Max external and Internal Leakage.
Overpressure 250 Pa |
1,9 |
% |
Max external and Internal Leakage.
Underpressure 250 Pa |
1,7 |
% |
Annual operation hours ta |
8760 |
h/a |
Primary energy factor pef |
2,5 |
|
Net ventilation rate qnet |
1,3 |
m³/hm² |
MISC (ducted) |
1,1 |
|
CTRL (local demand) |
0,65 |
|
X value.
Motor drive characteristic (Variable speed) |
2 |
|
SPI Specific power input (measurement) |
0,00053 |
kW/m³/h |
Total hours heating season th Average |
5112 |
h/a |
Total hours heating season th Cold |
6552 |
h/a |
Total hours heating season th Warm |
4392 |
h/a |
Average temperature difference ∆Th Average |
9,5 |
K |
Average temperature difference ∆Th Cold |
14,5 |
K |
Average temperature difference ∆Th Warm |
5 |
K |
Thermal efficiency ηh |
0,75 |
|
Specific heat capacity Cair |
0,000344 |
kWh/m³K |
Reference natural ventilation rate qref |
2,2 |
m³/hm³ |
Thermal efficiency of HRS ηt |
0,78 |
|
Defrosting period t defr Average |
168 |
h/a |
Defrosting period t defr Cold |
1003 |
h/a |
Defrosting period t defr Warm |
0 |
h/a |
Average temperature difference
defrost ∆Tdefr Average |
2,4 |
K |
Average temperature difference
defrost ∆Tdefr Cold |
5,2 |
K |
Average temperature difference
defrost ∆Tdefr Warm |
0 |
K |
AEC average. Annual electrical consumption
per 100 m² |
281 |
kWh/a |
AEC cold |
281 |
kWh/a |
AEC warm |
281 |
kWh/a |
AHS Average. Annual heating saved per m² |
44,4 |
kWh/a |
AHS Cold |
87,0 |
kWh/a |
AHS Warm |
20,1 |
kWh/a |
SEC Average. Specific energy consumption |
-37,4 |
kWh/m²a |
SEC Cold |
-79,9 |
kWh/m²a |
SEC Warm |
-13,1 |
kWh/m²a |
Efficiency Class |
A |
Document Name |
Model |
Language |
|
Bruks- og monteringsanvisning AHU-400 HV1 and HH1 | Norsk | ||
|
|||
Koblingsskjema/Wiring diagram AHU-400 HV and HH | Left/Right | Norsk/English | |
|
|||
|
|||