Ensy InoVent AHU 400 right and left variants are built for wall mounting, and suit larger apartments and single-family homes well. The models are based on the best of available technology which has resulted in energy efficiency and low noise level. Very user-friendly control
Ventilation unit
InoVent AHU 400 BR and BL
InoVent
Previous generation
TECHNICAL DATA AHU-400 BR and BL
| Heating coil | -phase/voltage | (50Hz/VAC) | ~1 / 230 |
| -power consumption | (W) | 1200 | |
| Fans | -phase/voltage | (50Hz/VAC) | ~1 / 230 |
| -Total current draw both fans at NORM operation | (A) | 0,21 | |
| Fuse size | (A) | 10 | |
| Control system | Integrated | ||
| Filter class | Superpleat | F7 | |
| Thermal insulation | (mm) | 40 | |
| Weight | (kg) | 64,5 | |


LYDDATA AHU – 400
| 63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | Lw(A) | ||
| Tilluft | -19 | -15 | -15 | -9 | -7 | -9 | -11 | -16 | 0,00 | |
| Frisk Luft | -25 | -17 | -12 | -8 | -7 | -10 | -15 | -23 | -1,77 | |
| Avkast | -19 | -14 | -16 | -8 | -6 | -9 | -16 | -21 | 1,30 | |
| Avtrekk | -28 | -19 | -13 | -5 | -15 | -13 | -19 | -28 | -2,14 | |
| Omgivelse (1,5m) | -5 | -10 | -15 | -20 | -28 | -33 | -32 | -31 | -20 | |
Korreksjon for lyd data omgivelse er kun gyldig i området for nominell luftmengde


LYDDATA AHU – 400
| 63Hz | 125Hz | 250Hz | 500Hz | 1kHz | 2kHz | 4kHz | 8kHz | Lw(A) | ||
| Tilluft | -19 | -15 | -15 | -9 | -7 | -9 | -11 | -16 | 0,00 | |
| Frisk Luft | -25 | -17 | -12 | -8 | -7 | -10 | -15 | -23 | -1,77 | |
| Avkast | -19 | -14 | -16 | -8 | -6 | -9 | -16 | -21 | 1,30 | |
| Avtrekk | -28 | -19 | -13 | -5 | -15 | -13 | -19 | -28 | -2,14 | |
| Omgivelse (1,5m) | -5 | -10 | -15 | -20 | -28 | -33 | -32 | -31 | -20 | |
Korreksjon for lyd data omgivelse er kun gyldig i området for nominell luftmengde
Dokumentnavn |
Modell |
Språk |
|
| |
Bruks- og Monteringsanvisning AHU-400 BR | Right | Norsk |
| |
Bruks- og Monteringsanvisning AHU-400 BL | Left | Norsk |
| |
Koblingsskjema/Wiring diagram AHU-400 BL BR | Left/Right | Norsk/English |