AHU 300 Himling is a ventilation unit in Ensy’s AHU series. AHU 300 Himling right and left variants have a capacity of approx. 300 m³/h and are well suited for apartments/small houses and single-family homes. The models are based on the best available technology which here has resulted in: Energy efficiency and low noise level. Very user-friendly control as well as an appealing design. AHU-300 Himling is built for ceiling mounting, alternatively wall mounting. The AHU units are of course developed to meet the requirements in today’s regulations. In addition, the units meet the requirements in the Passive House standard. Control panel with 10 meter cable is supplied loose together with the AHU unit.
AHU 300 Ceiling
TECHNICAL DATA AHU-300 Himling
| Varmebatteri | -fase/spenning | (50Hz/VAC) | ~1 / 230 |
| -effekt forbruk | (W) | 800 | |
| Vifter | -fase/spenning | (50Hz/VAC) | ~1 / 230 |
| -Totalt strømtrekk begge vifter ved NORM drift | (A) | 0,18 | |
| -turtall ved MAX drift | o/min | 2100 | |
| Sikringsstørrelse | (A) | 10 | |
| Automatikksystem | Integrert | ||
| Filterklasse | Superpleat | F7 | |
| Termisk isolasjon | (mm) | 40 | |
| Vekt | (kg) | 49,5 | |
|
Basic unit |
||
|
Trade name |
Ensy |
|
|
Product name |
AHU-300 HH AHU-300 HV |
|
|
ErP compliance |
2018 |
|
|
Unit category |
RVU |
|
|
Unit type |
BVU |
|
|
Drive |
Variable speed |
|
|
Heat recovery type |
Regenerative |
|
|
Thermal efficiency of HRS |
90 |
% |
|
qVd max |
240 |
m³/h |
|
PtU |
100 |
Pa |
|
P el,max |
243 |
W |
|
Sound power level Lwa |
43 |
dB(A) |
|
qv ref |
168 |
m³/h |
|
PtU ref |
50 |
Pa |
|
Max external and Internal Leakage.
Overpressure 250 Pa |
3.9 |
% |
|
Max external and Internal Leakage. Underpressure 250 Pa |
4.0 |
% |
|
Annual operation hours ta |
8760 |
h/a |
|
Primary energy factor pef |
2,5 |
|
|
Net ventilation rate qnet |
1,3 |
m³/hm² |
|
MISC (ducted) |
1,1 |
|
|
CTRL (local demand) |
0,65 |
|
|
X value.
Motor drive characteristic (Variable speed) |
2 |
|
|
SPI Specific power input (measurement) |
0,00046 |
kW/m³/h |
|
Total hours heating season th Average |
5112 |
h/a |
|
Total hours heating season th Cold |
6552 |
h/a |
|
Total hours heating season th Warm |
4392 |
h/a |
|
Average temperature difference ∆Th Average |
9,5 |
K |
|
Average temperature difference ∆Th Cold |
14,5 |
K |
|
Average temperature difference ∆Th Warm |
5 |
K |
|
Thermal efficiency ηh |
0,75 |
|
|
Specific heat capacity Cair |
0,000344 |
kWh/m³K |
|
Reference natural ventilation rate qref |
2,2 |
m³/hm³ |
|
Thermal efficiency of HRS ηt |
0,90 |
|
|
Defrosting period t defr Average |
168 |
h/a |
|
Defrosting period t defr Cold |
1003 |
h/a |
|
Defrosting period t defr Warm |
0 |
h/a |
|
Average temperature difference defrost ∆Tdefr Average |
2,4 |
K |
|
Average temperature difference defrost ∆Tdefr Cold |
5,2 |
K |
|
Average temperature difference defrost ∆Tdefr Warm |
0 |
K |
|
AEC average. Annual electrical consumption
per 100 m² |
244 |
kWh/a |
|
AEC cold |
244 |
kWh/a |
|
AEC warm |
244 |
kWh/a |
|
AHS Average. Annual heating saved per m² |
46,9 |
kWh/a |
|
AHS Cold |
91,8 |
kWh/a |
|
AHS Warm |
21,2 |
kWh/a |
|
|
-40,8 |
kWh/m²a |
|
SEC Cold |
-85,7 |
kWh/m²a |
|
SEC Warm |
-15,1 |
kWh/m²a |
|
Efficiency Class |
A |
|
Modell |
Språk |
||
| |
Koblingsskjema/Wiring diagram AHU-300 H | Høgre/Venstre | Norsk/English |
| |
Bruks- og Monteringsanvisning AHU-300 H | Høgre/Venstre | Norsk |