AHU 400 Ceiling/1
Ventilation unit

AHU 400 Ceiling/1

AHU series Current series

AHU 400 Himling is a ventilation unit in Ensy’s AHU series. The right and left variants of AHU 400 Himling have a capacity of approx. 400 m³/h and are well suited for apartments/small houses and single-family homes. The models are based on the best available technology, which here has resulted in: Energy efficiency and low noise level. Very user-friendly control as well as an appealing design. AHU-400 Himling is built for ceiling mounting, alternatively wall mounting. The AHU units are of course developed to meet the requirements of today’s regulations. In addition, the units meet the requirements of the Passive House standard. Control panel with 10 meter cable is supplied loose together with the AHU unit.

TECHNICAL DATA AHU-400 Himling

  Heating battery -phase/voltage (50Hz/VAC) ~1 / 230
-power consumption (W) 2x750
  Fans -phase/voltage (50Hz/VAC) ~1 / 230
-Total current draw both fans at NORM operation (A) 0,40
  Fuse size (A) 10
  Control system Integrated
  Filter class Superpleat F7
  Thermal insulation Sides/end walls 40 mm
Rear wall 20 mm
Front door 25 mm
  Weight (kg) 62

 

Trade name

Ensy

Product name

AHU-400 HH AHU-400 HV

ErP compliance

2016

Unit category

RVU

Unit type

BVU

Drive

Variable speed

Heat recovery type

Regenerative

Thermal efficiency of HRS

78

%

qVd max

420

m³/h

PtU

100

Pa

P el,max

350

W

Sound power level   Lwa

43

dB(A)

qv ref

294

m³/h

PtU ref

50

Pa

Max external and Internal Leakage. Overpressure 250 Pa

1,9

%

Max external and Internal Leakage. Underpressure 250 Pa

1,7

%

Annual operation hours   ta

8760

 h/a

Primary energy factor    pef

2,5

Net ventilation rate    qnet

1,3

m³/hm²

MISC (ducted)

1,1

CTRL (local demand)

0,65

X value.  Motor drive characteristic  (Variable speed)

2

SPI Specific power input  (measurement)

0,00053

kW/m³/h

Total hours heating season   th  Average

5112

h/a

Total hours heating season   th  Cold

6552

h/a

Total hours heating season   th  Warm

4392

h/a

Average temperature difference  ∆Th  Average

9,5

K

Average temperature difference  ∆Th  Cold

14,5

K

Average temperature difference  ∆Th  Warm

5

K

Thermal efficiency  ηh

0,75

Specific heat capacity   Cair

0,000344

kWh/m³K

Reference natural ventilation rate qref

2,2

m³/hm³

Thermal efficiency of HRS   ηt

0,78

Defrosting period   t defr  Average

168

h/a

Defrosting period   t defr  Cold

1003

h/a

Defrosting period   t defr  Warm

0

h/a

Average temperature difference defrost  ∆Tdefr  Average

2,4

K

Average temperature difference defrost  ∆Tdefr  Cold

5,2

K

Average temperature difference defrost  ∆Tdefr  Warm

0

K

AEC average. Annual electrical consumption per 100 m²

281

kWh/a

AEC cold

281

kWh/a

AEC warm

281

kWh/a

AHS Average. Annual heating saved per m²

44,4

kWh/a

AHS Cold

87,0

kWh/a

AHS Warm

20,1

kWh/a

SEC Average. Specific energy consumption

-37,4

kWh/m²a

SEC Cold

-79,9

kWh/m²a

SEC Warm

-13,1

kWh/m²a

Efficiency Class

A

 

Airflow (Supply) [m³/h]
Pressure (Supply) [PA]
AHU-400 HH

AHU-400 HV
AHU 400 Ceiling/1AHU 400 Ceiling/1
Airflow (Extract) [m³/h]
Pressure (Extract) [PA]
AHU-400 HH

AHU-400 HV
AHU 400 Ceiling/1AHU 400 Ceiling/1