AHU 400 Himling is a ventilation unit in Ensy’s AHU series. The right and left variants of AHU 400 Himling have a capacity of approx. 400 m³/h and are well suited for apartments/small houses and single-family homes. The models are based on the best available technology, which here has resulted in: Energy efficiency and low noise level. Very user-friendly control as well as an appealing design. AHU-400 Himling is built for ceiling mounting, alternatively wall mounting. The AHU units are of course developed to meet the requirements of today’s regulations. In addition, the units meet the requirements of the Passive House standard. Control panel with 10 meter cable is supplied loose together with the AHU unit.
AHU 400 Ceiling/1
TECHNICAL DATA AHU-400 Himling
| Heating battery | -phase/voltage | (50Hz/VAC) | ~1 / 230 |
| -power consumption | (W) | 2x750 | |
| Fans | -phase/voltage | (50Hz/VAC) | ~1 / 230 |
| -Total current draw both fans at NORM operation | (A) | 0,40 | |
| Fuse size | (A) | 10 | |
| Control system | Integrated | ||
| Filter class | Superpleat | F7 | |
| Thermal insulation | Sides/end walls | 40 mm | |
| Rear wall | 20 mm | ||
| Front door | 25 mm | ||
| Weight | (kg) | 62 |
|
Trade name |
Ensy |
|
|
Product name |
AHU-400 HH AHU-400 HV |
|
|
ErP compliance |
2016 |
|
|
Unit category |
RVU |
|
|
Unit type |
BVU |
|
|
Drive |
Variable speed |
|
|
Heat recovery type |
Regenerative |
|
|
Thermal efficiency of HRS |
78 |
% |
|
qVd max |
420 |
m³/h |
|
PtU |
100 |
Pa |
|
P el,max |
350 |
W |
|
Sound power level Lwa |
43 |
dB(A) |
|
qv ref |
294 |
m³/h |
|
PtU ref |
50 |
Pa |
|
Max external and Internal Leakage.
Overpressure 250 Pa |
1,9 |
% |
|
Max external and Internal Leakage.
Underpressure 250 Pa |
1,7 |
% |
|
Annual operation hours ta |
8760 |
h/a |
|
Primary energy factor pef |
2,5 |
|
|
Net ventilation rate qnet |
1,3 |
m³/hm² |
|
MISC (ducted) |
1,1 |
|
|
CTRL (local demand) |
0,65 |
|
|
X value.
Motor drive characteristic (Variable speed) |
2 |
|
|
SPI Specific power input (measurement) |
0,00053 |
kW/m³/h |
|
Total hours heating season th Average |
5112 |
h/a |
|
Total hours heating season th Cold |
6552 |
h/a |
|
Total hours heating season th Warm |
4392 |
h/a |
|
Average temperature difference ∆Th Average |
9,5 |
K |
|
Average temperature difference ∆Th Cold |
14,5 |
K |
|
Average temperature difference ∆Th Warm |
5 |
K |
|
Thermal efficiency ηh |
0,75 |
|
|
Specific heat capacity Cair |
0,000344 |
kWh/m³K |
|
Reference natural ventilation rate qref |
2,2 |
m³/hm³ |
|
Thermal efficiency of HRS ηt |
0,78 |
|
|
Defrosting period t defr Average |
168 |
h/a |
|
Defrosting period t defr Cold |
1003 |
h/a |
|
Defrosting period t defr Warm |
0 |
h/a |
|
Average temperature difference
defrost ∆Tdefr Average |
2,4 |
K |
|
Average temperature difference
defrost ∆Tdefr Cold |
5,2 |
K |
|
Average temperature difference
defrost ∆Tdefr Warm |
0 |
K |
|
AEC average. Annual electrical consumption
per 100 m² |
281 |
kWh/a |
|
AEC cold |
281 |
kWh/a |
|
AEC warm |
281 |
kWh/a |
|
AHS Average. Annual heating saved per m² |
44,4 |
kWh/a |
|
AHS Cold |
87,0 |
kWh/a |
|
AHS Warm |
20,1 |
kWh/a |
|
|
-37,4 |
kWh/m²a |
|
SEC Cold |
-79,9 |
kWh/m²a |
|
SEC Warm |
-13,1 |
kWh/m²a |
|
Efficiency Class |
A |
Document Name |
Model |
Language |
|
| |
Bruks- og monteringsanvisning AHU-400 HV1 og HH1 | Norsk | |
| |
Koblingsskjema/Wiring diagram AHU-400 HV and HH | Left/Right | Norsk/English |